It took me few hours to slap together this simple VB6 test code to read DS18S20 through IOM#142A made by Peter H. Anderson. The fastest reliable reading it can do is 1 readings every 2 seconds. For slower readings increase the MEASUREMENT_INTERVAL constant (in milliseconds).

The code is using MSComm control & Timer control. The main work is done by the clsComReader class:

Option Explicit

' clsComReader
'
' 1. instantiate
' 2. set timer & (optional) Interval
' 3. set comm (that will start the first measurement)
'
' 4. handle GotData or read Measurement & MeasurementTime
'
' does one measurement only when interval not set or set to 0
' you can force next measurement calling RequestMeasurement
' use GotData callback or wait for MeasurementTime <> "" to get the first value
'

Public Event GotData()

Private Const MEASUREMENT_DELAY = 1400

Private buffer As Variant
Private mTemperature As String
Private mMeasurementTime As Date
Private mInterval As Long ' milliseconds
Private mSendRequest As Boolean

Private WithEvents oTimer As Timer
Private WithEvents oComm As MSComm


Public Property Set Timer(ByVal Value As Timer)
    Set oTimer = Value
End Property


Public Property Set CommControl(ByVal Value As MSComm)
   
    Set oComm = Value
    ' 9600 baud, no parity, 8 data, and 1 stop bit.
    oComm.Settings = "9600,N,8,1"
    ' Tell the control to read entire buffer when Input is used.
    oComm.InputLen = 0
    oComm.DTREnable = False
    oComm.PortOpen = True
    RequestMeasurement

End Property


Public Property Let Interval(ByVal Value As Long)
   
    If Value > 0 Then
        mInterval = Value - MEASUREMENT_DELAY
        If mInterval < 0 Then
            mInterval = 10
        End If
    Else
        mInterval = 0
    End If

End Property


Public Property Get Interval() As Long
   
    If mInterval > 0 Then
        Interval = mInterval + MEASUREMENT_DELAY
    Else
        Interval = 0
    End If

End Property


Public Property Get Measurement() As String
   
    Measurement = mTemperature

End Property


Public Property Get MeasurementTime() As String
   
    MeasurementTime = mMeasurementTime

End Property


Public Sub RequestMeasurement()

    oTimer.Interval = MEASUREMENT_DELAY
    oComm.Output = buffer
    mSendRequest = False

End Sub


Private Sub Class_Initialize()

    buffer = "D0" & vbCr
    mInterval = 0
    mSendRequest = False

End Sub


Private Sub oTimer_Timer()

    If mSendRequest Then
        RequestMeasurement
    Else
        oTimer.Interval = mInterval
        mMeasurementTime = Now()
        mTemperature = oComm.Input
        mSendRequest = True
        RaiseEvent GotData
    End If

End Sub


Private Sub oComm_OnComm()
   
    Select Case oComm.CommEvent
   ' Handle each event or error by placing
   ' code below each case statement

   ' Errors
      Case comEventBreak   ' A Break was received.
'        Me.Label1.Caption = "br"
      Case comEventFrame   ' Framing Error
'        Me.Label1.Caption = "fr"
      Case comEventOverrun   ' Data Lost.
'        Me.Label1.Caption = "ov"
      Case comEventRxOver   ' Receive buffer overflow.
'        Me.Label1.Caption = "rx"
      Case comEventRxParity   ' Parity Error.
'        Me.Label1.Caption = "pa"
      Case comEventTxFull   ' Transmit buffer full.
'        Me.Label1.Caption = "full"
      Case comEventDCB   ' Unexpected error retrieving DCB]
'        Me.Label1.Caption = "dcb"

   ' Events
      Case comEvCD   ' Change in the CD line.
''        Me.Label1.Caption = "cd " & MSComm1.Input
      Case comEvCTS   ' Change in the CTS line.
''        Me.Label1.Caption = "cts " & MSComm1.Input
      Case comEvDSR   ' Change in the DSR line.
''        Me.Label1.Caption = "dts"
      Case comEvRing   ' Change in the Ring Indicator.
''        Me.Label1.Caption = "ring"
      Case comEvReceive   ' Received RThreshold # of
                        ' chars.
 '       Me.Label1.Caption = "R " & MSComm1.Input
      Case comEvSend   ' There are SThreshold number of
                     ' characters in the transmit
                     ' buffer.
 '       Me.Label1.Caption = "send"
      Case comEvEOF   ' An EOF charater was found in
                     ' the input stream
 '       Me.Label1.Caption = "E " & MSComm1.Input
   End Select

End Sub


Private Sub Class_Terminate()

    oTimer.Interval = 0
    oComm.PortOpen = False
    Set oTimer = Nothing
    Set oComm = Nothing

End Sub

For whatever reason, the onComm event is invoked only when the IOM is not receiving & need to be reset. Therefore I commented it out & so I can research it later.

There is one form with one large label Label1, timer control Timer1 and communication control MSComm1 with the code:

Option Explicit

Private Const MEASUREMENT_INTERVAL = 2000 ' 2 seconds

Private WithEvents oComReader As clsComReader


Private Sub Form_Load()

    Me.Label1.Caption = ""

    Set oComReader = New clsComReader
    Set oComReader.Timer = Me.Timer1
    oComReader.Interval = MEASUREMENT_INTERVAL
    Set oComReader.CommControl = Me.MSComm1

End Sub


Private Sub oComReader_GotData()
   
    Label1.Caption = oComReader.MeasurementTime & vbCr & oComReader.Measurement

End Sub


Private Sub Form_Unload(Cancel As Integer)
   
    Set oComReader = Nothing

End Sub

The next version will separate the device number & measured value from the response & it should enable more devices on 1-Wire line. I am still waiting for additional DS1820 to try that...